BQQCW - SULFURIC ACID, A-298

  • MSDS: BQQCW
  • Manufacturer: E C APPARATUS CORP
  • Product Name: SULFURIC ACID, A-298
  • National Stock Number: 6810-00-072-2921
Product Identification

Product ID:SULFURIC ACID, A-298
MSDS Date:09/15/1988
FSC:6810
NIIN:00-072-2921
MSDS Number: BQQCW

Responsible Party
E-C APPARATUS CORP
3831 TYRONE BLVD N
ST PETERSBURG, FL 33709
US

Emergency Phone: 813-344-1644

Info Phone: 813-344-1644

Cage: 23605

Contractor
E-C APPARATUS CORP
SAINT PETERSBURG, FL 33709-4121 US

Telephone: 813-344-1644

Cage: 23605

Ingredients

SULFURIC ACID (SARA III)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 98%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 2 - 7%


CONFINED SPACES. RUNOFF TO SEWER

RTECS: 9999999ZZ


SEVERE DMG, OFTEN LEADING TO BLINDESS.

RTECS: 9999999ZZ


RECOVERY MAY BE COMPLETE. EXPOSURE TO THE MIST

RTECS: 9999999ZZ


MAY CAUSE CONJUNCTIVITIS AND LACRIMATION. INGEST

RTECS: 9999999ZZ


FOLLOWED BY VOMITING & DIRRHEA OF DARK, PRECIPITATED

RTECS: 9999999ZZ


PERFORATION OF THE ESOPHAGUS AND STOMACH MAY OCCUR.

RTECS: 9999999ZZ


OCCASNLY LIFTING THE UPPER & LOWER LIDS,

RTECS: 9999999ZZ


APPLY STERILE BANDAGES LOOSELY WITHOUT MEDICATION.

RTECS: 9999999ZZ


QUANTITIES OF WATER IMMEDIATELY TO DILUTE THE ACID.

RTECS: 9999999ZZ


W/SLAKED LIME, SODIUM BICARBONATE/CRUSHED

RTECS: 9999999ZZ


NEUT W/AGRICULTURAL LIME, SLAKED

RTECS: 9999999ZZ


SUITABLE AGENT TO NEUTRALIZE SPILLED MATL TO PH-7.

RTECS: 9999999ZZ


AWAY FROM SPILLED MATL. DO NOT TOUCH SPILLED MATL.

RTECS: 9999999ZZ


IT WITHOUT RISK. USE WATER SPRAY TO REDUCE VAPS. DO

RTECS: 9999999ZZ


THE SUPERVISION OF AN EXPERT. DIKE SPILL FOR LATER

RTECS: 9999999ZZ


KEEP UNNEC PEOPLE AWAY. ISOLATE HAZARD AREA AND

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) 2140 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:CORROSIVE/TOXIC. ACUTE: EXPOSURE
TO CONC CNTNG 5 MG/M3 MAY CAUSE NOSE & THROAT IRRIT, HDCH, COUGH,
AN INCR IN RESP RATE/IMPAIRMENT OF VENT CAPACITY. DELAYED SYMPS MAY
INCL PULM EDEMA, TIGHTNESS IN CHEST, CYANOSIS, HYPOTENSION,
BRONCHITIS OR EMPHYSEMA. CHRONIC: RPTD EXPOS TO MIST CAUSES
CHRONIC(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:TRACHEO-BRONCHITIS, EROSION &
DISCOLORATION OF TEETH, BRONCHIAL PNMEUMONIA OR GI DISTRUBANCES.
SKIN:CORROSIVE. ACUTE:CNTCT MAY CAUSE SEVERE IRRIT & PAIN, BURNS &
VESICULATION. CHRONIC:RPTD/PR LNGD EXPOS TO LIQ/MIST MAY CAUSE
IRRIT & DERM. EYE:CORROSIVE. ACUTE:DIRECT CNTCT W/CONC ACID SOLN
MAY CAUSE (ING 4)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP). SKIN: REMOVE CONTAM CLTHG & SHOES IMMED. WASH AFFECTED AREA
W/SOAP OR MILD DETERGENT & LRG AMTS OF WATER UNTIL NO EVIDENCE OF
CHEM REMAINS. IN CASE OF BURNS, COVER THE AREA WITH STERILE, DRY
DRESSING. BANDANGE SECURELY, BUT NOT TOO TIGHTLY. GET MED ATTN.
EYES:WASH IMMED W/LRG AMTS OF WATER FOR AT LEAST 15 MIN, (ING 9)

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:DRY CHEM/CARBON DIOXIDE (1984 EMERGENCY RESPONSE
GUIDEBOOK, DOT P 5800.3) LRG FIRES: FLOOD AREA W/WATR FROM A
DISTANCE.
Fire Fighting Procedures:MOVE CNTNRS FROM FIRE AREA IF POSS.COOL
EXPOSED CNTNRS W/H*2O FROM SIDE UNTIL AFTER FIRE IS OUT.WEAR
NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP. (SUPP DATA)
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:SOIL SPILL:DIG HOLDING AREA SUCH AS LAGOON,
POND OR PIT FOR CONTAMINANT. DIKE FLOW OF SPILLED MATERIAL USING
SOIL OR SANDBAGS OR FOAMED BARRIERS SUCH AS POLYURETHANE OR
CONCRETE. USE CEMENT POWDER OR FLY ASH TO ABSORB LIQUID MASS. NEUT
SPILL(ING 12)
Neutralizing Agent:SEE SPILL PROCEDURES.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . 50 MG/M3: GMOVC, SAF, SCBA, HEPA. 100 MG/M3:
SAF. ESCAPE: GMOVC, SCBA. FIRE FIGHTING: SCBA.
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION SYSTEM TO MEET
PERMISSIBLE EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOGG/FULL LENGTH FSHLD .
Other Protective Equipment:EMPLOYER SHALL PROVIDE AN EYE-WASH FOUNTAIN
WITHIN THE IMMEDIATE WORK AREA FOR EMERGENCY USE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:EXTING USING AGENTS INDICATED; DO NOT USE WATER
DIRECTLY ON MATL. IF LRG AMTS OF COMBUST MATLS ARE INVOLVED, USE
WATER SPRAY OR FOG IN FLOODING AMTS. USE WATER SPRAY TO ABSORB
CORROSIV E VAPORS. COOL CNTNRS W/FLOODING AMTS OF WATER FROM AS FAR
A DISTANCE AS POSS. AVOID BRTHG CORR VAPS; KEEP UPWIND.

Chemical Properties

Boiling Pt:B.P. Text:536F,280C
Melt/Freeze Pt:M.P/F.P Text:37.0F,2.8C
Vapor Pres:0.001@ 20C
Vapor Density:3.4
Spec Gravity:1.8
Solubility in Water:SOLUBLE
Appearance and Odor:COLORLESS TO DARK BROWN, OILY LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
ALCOHOLS & HYDROGEN PEROXIDE, AMMONIUM HYDROXIDE, CHLORATE, METALS
(POWDERED), PERCHLORATES, STEEL.
Stability Condition to Avoid:MAY IGNITE OTHER COMBUST MATLS
(WOOD,PAPER,OIL,ETC). VIOLENT RXN W/H*2O & ORG MATL. FLAMM,POISON
GAS MAY ACCUM IN(ING 3)
Hazardous Decomposition Products:THERMAL DECOMPOSITION PRODUCTS INCLUDE
HIGHLY TOXIC FUMES OF SULFUR OXIDES.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.